next up previous contents index
Next: Impulse responses of recirculating Up: Designing filters Previous: Butterworth band-pass filter   Contents   Index


Time-varying coefficients

In some recursive filter designs, changing the coefficients of the filter can inject energy into the system. A physical analogue is a child on a swing set. The child oscillates back and forth at the resonant frequency of the system, and pushing or pulling it injects or extracts energy smoothly. However, if you decide to shorten the chain or move the swingset itself, you may inject an unpredictable amount of energy into the system. This corresponds to changing the coefficients in a resonant recirculating filter.

Happily, the simple one-zero and one-pole filters used here don't have this difficulty; if the feedback or feed-forward gain is changed smoothly (in the sense of an amplitude envelope) the output will behave smoothly as well.

The only subtlety arises when trying to normalize a recursive filter's output when the feedback gain is close to one. For example, suppose we have a one-pole low-pass filter with gain 0.99 (for a cutoff frequency of 0.02 radians, or 47 Hz. at the usual sample rate). To normalize this for unit DC gain we multiply by 0.01. Suppose now we wish to double the cutoff frequency by changing the gain imperceptibly to 0.98. This is fine except that the normalizing factor suddenly doubles. If we multiply the filter's output by the normalizing factor, the output will suddenly, although perhaps only momentarily, jump by a factor of two.

Figure 8.21: Normalizing a recirculating elementary filter: (a) correctly, by multiplying in the normalization factor at the input; (b) incorrectly, multiplying at the output.
\begin{figure}\psfig{file=figs/fig08.21.ps}\end{figure}

The trick is to normalize at the input of the filter, not the output. Figure 8.21 part (a) shows a complex recirculating filter, with feedback gain $P$, normalized at the input by $1-\vert P\vert$ so that the peak gain is one. Part (b) shows the wrong way to do it, multiplying at the output.

Things get more complicated when several elementary recirculating filters are put in series, since the correct normalizing factor is in general a function of all the coefficients. One possible approach, if such a filter is required to change rapidly, is to normalize each input separately as if it were acting alone, then multiplying the output, finally, by whaever further correction is needed.


next up previous contents index
Next: Impulse responses of recirculating Up: Designing filters Previous: Butterworth band-pass filter   Contents   Index
Miller Puckette 2006-03-03